ThermistorCalibrationEquationHoge2 function

Resistance–temperature calibration equation Hoge 1

Resistance–temperature calibration equation Hoge 1

ThermistorCalibrationEquationHoge2 Resistance–temperature calibration equation Hoge 2

ThermistorCalibrationEquationHoge2(Rt, A0, A1, A2, A3)

Arguments

  • Rt: resistance measurement for temperature T
  • A0: equation coefficient A0
  • A1: equation coefficient A1
  • A2: equation coefficient A2
  • A3: equation coefficient A3

Returns

  • T: temperature

Source

Chiachung Chen, 2009 Evaluation of resistance–temperature calibration equations for NTC thermistors Measurement 42, Elsevier

References

Chiachung Chen, 2009 Evaluation of resistance–temperature calibration equations for NTC thermistors Measurement 42, Elsevier

Author(s)

Jose Gama

  • Maintainer: Jose Gama
  • License: GPL (>= 3)