Calculate Practical Salinity from salinometer readings of conductivity ratio and bath temperature.
gsw_SP_salinometer(ratio, temperature)
Arguments
ratio: Conductivity ratio [ unitless ]. (This is called Rt in the GSW documentation.)
temperature: Bath temperature [ degC ]. (This is called t in the GSW documentation.)
Returns
Practical salinity on the PSS-77 scale [ unitless ]
Implementation Note
This R function uses a wrapper to a C function contained within the GSW-C system as updated 2022-10-11 at https://github.com/TEOS-10/GSW-C with git commit 657216dd4f5ea079b5f0e021a4163e2d26893371.
The C function uses data from the library/gsw_data_v3_0.mat
file provided in the GSW-Matlab source code, version 3.06-11. Unfortunately, this version of the mat file is no longer displayed on the TEOS-10.org website. Therefore, in the interests of making GSW-R be self-contained, a copy was downloaded from http://www.teos-10.org/software/gsw_matlab_v3_06_11.zip on 2022-05-25, the .mat file was stored in the developer/create_data directory of https://github.com/TEOS-10/GSW-R, and then the dataset used in GSW-R was created based on that .mat file.
Please consult http://www.teos-10.org to learn more about the various TEOS-10 software systems.
Examples
ratio <- c(0.9345,0.95123,0.91807,0.8886,0.8169,0.6687)temperature <- c(28.7856,28.4329,22.8103,10.2600,6.8863,4.4036)SP <- gsw_SP_salinometer(ratio, temperature)stopifnot(all.equal(SP, c(32.431728787558541,33.085035719966307,31.800791917322833,30.692490757036179,27.979281308696116,22.474597460508491)))